LI Ling-xiao, ZHANG Kai, QU Jia-chuang, et al. STIRLING CRYOCOOLER CONTAMINATION FAILURE RESEARCH[J]. VACUUM AND CRYOGENICS, 2015, 21(6): 311-314,342. DOI: 10.3969/j.issn.1006-7086.2015.06.001
Citation: LI Ling-xiao, ZHANG Kai, QU Jia-chuang, et al. STIRLING CRYOCOOLER CONTAMINATION FAILURE RESEARCH[J]. VACUUM AND CRYOGENICS, 2015, 21(6): 311-314,342. DOI: 10.3969/j.issn.1006-7086.2015.06.001

STIRLING CRYOCOOLER CONTAMINATION FAILURE RESEARCH

  • Contamination caused by stirling cryocooler outgassing becomes a crucial factor that impacts cryocooler´s life.Concaminants in cryocooler will leads to the rubbing of mechanical parts or blockage of flow,which in turn reduces cooler life and/or degrades performance.Accelerated lifetime evaluation technique and numerical analytical methods were introduced.Some suggestions and techniques about cryoclooler contamination failure were discussed.