GUO Ning, QIU Jia-wen, GU Zuo, et al. 20 cm XENON ION ENGINE HOLLOW CATHODE 3 000 HOURS LIFE-TEST[J]. VACUUM AND CRYOGENICS, 2006, 12(4): 204-206.
Citation: GUO Ning, QIU Jia-wen, GU Zuo, et al. 20 cm XENON ION ENGINE HOLLOW CATHODE 3 000 HOURS LIFE-TEST[J]. VACUUM AND CRYOGENICS, 2006, 12(4): 204-206.

20 cm XENON ION ENGINE HOLLOW CATHODE 3 000 HOURS LIFE-TEST

  • Ongoing life-test of hollow cathode has been introduced.The result indicated that the performance of hollow cathode has not show degradation trend after 3 000 hours life-test.The result has also showed the hollow cathode has good antipoisoning traits under air exposure condition.