张开, 索晓晨, 黄潇博, 等. 电喷推力器稳定域研究与性能测试[J]. 真空与低温, 2022, 28(6): 642-649. DOI: 10.3969/j.issn.1006-7086.2022.06.003
引用本文: 张开, 索晓晨, 黄潇博, 等. 电喷推力器稳定域研究与性能测试[J]. 真空与低温, 2022, 28(6): 642-649. DOI: 10.3969/j.issn.1006-7086.2022.06.003
ZHANG Kai, SUO Xiaochen, HUANG Xiaobo, et al. Characterizations of the Stable Operational Range and Thrust Control Features of a Colloid Thruster[J]. VACUUM AND CRYOGENICS, 2022, 28(6): 642-649. DOI: 10.3969/j.issn.1006-7086.2022.06.003
Citation: ZHANG Kai, SUO Xiaochen, HUANG Xiaobo, et al. Characterizations of the Stable Operational Range and Thrust Control Features of a Colloid Thruster[J]. VACUUM AND CRYOGENICS, 2022, 28(6): 642-649. DOI: 10.3969/j.issn.1006-7086.2022.06.003

电喷推力器稳定域研究与性能测试

Characterizations of the Stable Operational Range and Thrust Control Features of a Colloid Thruster

  • 摘要: 电喷推力器在立方星变轨、离轨以及编队飞行等方面具有良好的应用前景,尤其可以在空间引力波探测等无拖曳控制任务中发挥重要作用。使用微针作为电喷推力器发射极,通过调控压力对工质流量进行主动控制,实现了以流量和电压为变量的推力调控策略。面向我国引力波探测任务需求,针对微牛顿量级电喷推力器开展研制工作,重点研究微针发射极类型电喷推力器的推力调控特性,对研制的单发射极毛细管电喷推力器发射原理试验系统的稳定工作范围(稳定域)、电压、流量调控特征以及推力范围、推力噪声、推力分辨率、推力变化响应时间等关键性能参数进行了研究与测试。试验结果表明,该推力器的推力范围为0.5~8.5 μN,推力噪声小于0.1 μN/Hz0.5,推力分辨率小于0.1 μN,推力随电压变化响应时间小于10 ms。

     

    Abstract: The colloid thruster has good application prospects in the orbit change,deorbit and formation flight of the cubic satellite,especially in the no drag control task of space gravitational wave detection.Using the microneedle tube as the emitter of the colloid thruster,the flow of the working fluid can be actively controlled by adjusting the pressure,and the thrust control strategy with the flow and voltage as variables is realized.The Center for Gravitational Experiments of Huazhong University of Science and Technology is oriented to the needs of China’s gravitational wave detection missions,and is developing the micro-Newton-level colloid thruster,focusing on the thrust control characteristics of the micro-needle emitter type colloid thruster.In order to further study its working characteristics,this paper analyzes the stable operational range,voltage and flow rate control characteristics of the thruster prototype.Key performance parameters such as thrust range,thrust noise,thrust resolution and thrust change response time etc.were tested.The results show that the thrust range of the thruster is 0.5~8.5 μN,the thrust noise is less than 0.1 μN/Hz0.5,the thrust resolution is about 0.04 μN when the 100 V voltage changes,and the thrust change response time is less than 10 ms when the thrust changes with voltage.

     

/

返回文章