单级逆升压空气制冷系统在房间空调中的应用

APPLICATON OF SIMPLE NEGATIVE PRESSURE-BOOSTING CIRCUIT OF AIR CYCLE AIR CONDITIONING IN ROOM

  • 摘要: 研究了单级逆升压式房间空气制冷系统的流程,计算了各状态点热力参数,提出了需要解决的关键技术难题。结论认为,房间空调制冷系数可达1.72,制热系数达1.71,是较有前途的绿色环保型空调。

     

    Abstract: The simple negative pressure-boosting circuit of air cycle air conditioning in room is presented. Thermodynamics parameters of every working state are caluclated. The problems of key technology to be solved are discussed. The conclusion is that the refrigeration efficiency of air cycle air conditioning in room can reach to 1.72, the heating efficiency also can reach to 1.71. This new kind of air cycle air conditioning in room is friendly environmental and promisimg.

     

/

返回文章
返回